Home Muffle Furnace

Muffle Furnace



With sillimanite muffle with smooth internal surface, imported KANTHAL A-1 heating elements are provided all around the heating chamber backed by ceramic fiber insulation.  A safety protection fuse is to be provided. A simple flap type of door with a spy hole for viewing the Chamber.
Control system: Consists of an energy regulator, digital temperature controller, chromel / alumel thermocouple, Indicating lamps, etc. which will be mounted on the top of the furnace.
Supplied complete with 2 meters of 3 core wire with 3 pin plug for operation on 230 volts single phase 50 c/s AC mains.
Temperature range: Maximum temperature upto 1000°C. and recommended regular working  Temperature not to exceed 930°C

Inner size Rating

   4” x 4” x 9”

  1.75 KW

  5” x 5” x 10”

  2.50 KW

  5” x 5” x 12”

  3.00 KW

  6” x 6” x 12”

  3.30 KW

  8” x 8” x 12”

  4.50 KW

 

 

 

Atomic Absorption Spectrophotometer (AAS)



SALIENT FEATURES

  • Built in PC 7" High Resolution Touch Screen LCD Color Graphical Display
  • Automated (6/8)  lamp turret compatible to coded & non-coded HCL Lamps with independent Power Supply for warm-up
  • High Energy True Double Beam Optics with Narrow Beam, fully sealed and Quartz over coated mirrors
  • Background correction with D2 lamp source
  • Integral Auto gas control system with LCD display
  • Automatic Ignition and Flame Control with Full Saftey Interlocks
  • Automatic Lamp Alignment
  • Burner Movement in all three directions - height, rotation and lateral.
  • Modes of operation include Absorbance, Emission, Concentration and Standard Addition
  • Optional : 21 CFR Part 11 PC Software, Auto Sampler, Hydride and Cold Vapour Generator, Graphite Furnance.

 

 

COD DIGESTER



Digital COD Digesters apparatus  is a solid block heated unit with provision for 15 samples at a time in 40mm dia Reaction Vessel. All the samples are heated at 150 deg. C within +-1% accuracy with utmost uniformity of temperature.

Specifications:

  • Glassware: 15 Reaction Vessels & Air Condensers.
  • Temperature: 150°C ± 1%
  • Capacity: 15 samples at a time.
  • Sample Size: 20 ml
  • Range: 0 to 500 ppm without dilution. Further samples can be analysed using appropriate dilution.
  • Timer: 2 hours timer with Buzzer
  • Overall Dimensions: 475 x 295 x 200mm
  • Power Requirement: 230V 1000W

BOD Incubator



SPECIFICATION:

Temperature range 0°C to 60°C

Unique design of thermal barrier for better energy efficiency

Machine filled PUF insulation to eliminate void pockets

Powerful fan motor for forced air circulation to maintain uniform conditions inside chamber

Heating by long life SS tubular heaters

Chamber calibration port on side

Adjustable trays

Hermetically sealed Compressor with CFC free refrigerant

High temperature safety cut off & alarms for high / low set parameters

Sensor failure alarm

Electrical circuit breaker

Time delay for compressor switch on

Overload cut off relay for compressor

Rounded inner chamber for easy cleaning

Attractive door profile

Further More Details